Why kitchens overheat and dining rooms fill with smoke, and what fixes it.

Reviewed by Abdullah Ghzail, licensed gas technician•Last checked November 2026

Quick answer: A restaurant that is hot, smoky or hard to keep comfortable usually has an air balance problem: the kitchen exhaust is removing more air than the make-up air unit and rooftop units are bringing back. Dirty filters, a failed make-up air unit or a rooftop unit that is down are the usual causes.

Ductless wall unit installed in a restaurant
Rooftop units serving a London-area restaurant. Photo: Hawana HVAC Solutions.

Symptoms and likely causes

SymptomLikely cause
Kitchen very hotMake-up air off or weak; rooftop unit not cooling; hood not capturing
Smoke rolling out of the hoodExhaust fan belt, grease-loaded filters, or negative pressure pulling air the wrong way
Front door hard to open, whistlingBuilding under negative pressure
Dining room hot in summerRooftop unit undersized, dirty or low on refrigerant
Cold blasts at tables in winterMake-up air burner not firing
Water dripping from ceiling tilesBlocked rooftop unit drain
Pilot lights blowing outNegative pressure or drafts from make-up air

What to check yourself

  1. Are the hood and the make-up air unit both switched on?
  2. Are the hood grease filters clean and in place?
  3. Are the rooftop unit filters overdue?
  4. Is every thermostat set to Cool or Auto, not Off or Fan?

What a technician checks

  • Exhaust and make-up airflow, and whether they are balanced
  • Belts, motors and fan direction
  • Refrigerant pressures and coil condition on the rooftop units
  • Make-up air burner and safety controls
  • Controls that tie the hood and make-up air together

Adding cooling to a hot spot

A ductless unit can cool a dining area, an office or a prep area that the main system cannot reach.

Prevent it

Quarterly maintenance with filter changes keeps airflow where it should be. More: make-up air units and maintenance contracts.

Common questions

Why is my restaurant kitchen so hot?

Usually the make-up air unit is off or weak, the hood is not capturing heat, or the rooftop unit serving the kitchen is not cooling.

Why is smoke coming out of my kitchen hood?

A slipping exhaust fan belt, clogged grease filters, or negative building pressure pulling air back out of the hood.

How often should restaurant HVAC be serviced?

At least quarterly, with rooftop filters changed every one to three months.

Call Hawana (519) 851-8518